Renesas Electronics /R7FA6M1AD /CAN0 /MIER_FIFO

Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text Text

Interpret as MIER_FIFO

31 2827 2423 2019 1615 1211 87 43 0 0 0 0 0 0 0 0 00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 (0)MB0 0 (0)MB1 0 (0)MB2 0 (0)MB3 0 (0)MB4 0 (0)MB5 0 (0)MB6 0 (0)MB7 0 (0)MB8 0 (0)MB9 0 (0)MB10 0 (0)MB11 0 (0)MB12 0 (0)MB13 0 (0)MB14 0 (0)MB15 0 (0)MB16 0 (0)MB17 0 (0)MB18 0 (0)MB19 0 (0)MB20 0 (0)MB21 0 (0)MB22 0 (0)MB23 0 (0)MB24 0 (0)MB25 0 (0)MB28 0 (0)MB29

MB15=0, MB5=0, MB21=0, MB25=0, MB19=0, MB14=0, MB6=0, MB9=0, MB4=0, MB3=0, MB2=0, MB28=0, MB7=0, MB12=0, MB1=0, MB0=0, MB17=0, MB13=0, MB10=0, MB16=0, MB22=0, MB8=0, MB23=0, MB20=0, MB29=0, MB24=0, MB11=0, MB18=0

Description

Mailbox Interrupt Enable Register for FIFO Mailbox Mode

Fields

MB0

mailbox 0 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB1

mailbox 1 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB2

mailbox 2 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB3

mailbox 3 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB4

mailbox 4 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB5

mailbox 5 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB6

mailbox 6 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB7

mailbox 7 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB8

mailbox 8 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB9

mailbox 9 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB10

mailbox 10 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB11

mailbox 11 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB12

mailbox 12 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB13

mailbox 13 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB14

mailbox 14 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB15

mailbox 15 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB16

mailbox 16 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB17

mailbox 17 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB18

mailbox 18 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB19

mailbox 19 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB20

mailbox 20 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB21

mailbox 21 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB22

mailbox 22 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB23

mailbox 23 Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB24

Transmit FIFO Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB25

Transmit FIFO Interrupt Generation Timing Control

0 (0): Every time transmission is completed

1 (1): When the transmit FIFO becomes empty due to completion of transmission

MB28

Receive FIFO Interrupt Enable

0 (0): Interrupt disabled

1 (1): Interrupt enabled

MB29

Receive FIFO Interrupt Generation Timing Control

0 (0): Every time reception is completed

1 (1): When the receive FIFO becomes buffer warning by completion of reception

Links

()